亚洲日韩Av中文字幕无码,国产精品自产拍在线观看中文,久久亚洲春色中文字幕久久久,亚洲性爱无码视频在线观看
產(chǎn)品banner

您當(dāng)前的位置 : 首 頁 > 產(chǎn)品中心 > 日本YUKEN油研

產(chǎn)品中心 Product

聯(lián)系我們Contact Us

上海乾拓貿(mào)易有限公司

電 話:021-39526589

網(wǎng)址:m.sh-hancheng.cn

地 址:上海嘉定區(qū)嘉涌路99弄6號(hào)樓713室

日本YUKEN進(jìn)給控制閥技術(shù)樣本

日本YUKEN進(jìn)給控制閥技術(shù)樣本

  • 所屬分類:日本YUKEN油研
  • 瀏覽次數(shù):
  • 發(fā)布日期:2017-11-24
  • 產(chǎn)品概述
  • 性能特點(diǎn)
  • 技術(shù)參數(shù)

日本YUKEN進(jìn)給控制閥技術(shù)樣本

上海乾拓貿(mào)易有限公司

聯(lián)系人:楊江玲

企業(yè)QQ:2880626083

手 機(jī):18917074297(微信)

電 話:021-39529830-8012

郵箱;18917074297@163.com

地址:上海市嘉定區(qū)江橋嘉涌路6號(hào)樓713室   

in the installation drawings. Allowable drain port back pressure Limit to 0.1 MPa (15 PSI). 

Japanese Std. "JIS" & European Design Std. N. American Design Std.

UCF1G-01  UCF1G-03  UCF2G-03  UCF1G-04  UCF2G-04

These valves are the combination of flow control valve, a deceleration valve 

the hydraulic fluids which may otherwise l ead to breakdowns and shorten the life of the valves.

Recommended Viscosity and Oil Temperatures 2  Viscosity ranging between 15 - 400 mm /s 

(77 - 1800 SSU).  Oil temperatures between -15/+70°C (5 - 158°F). 

 Use hydraulic fluids which satisfy the recommended viscosity and oil temperatures given above.

Use fluids equivalent to ISO VG 32 or VG 46. Use phosphate ester or polyol ester fluid. 

When phosphate ester fluid is used, prefix "F-" to the model number because the special seals 

(fluororubber) are required to be used. Use water-glycol fluid.

M6 × 55 Lg.  M6 × 55 Lg.  M6 × 55 Lg.  M10 × 70 Lg.  M10 × 70 Lg.

and fine feed control is accomplished by dial rotation regardless of pressure 

and oil temperature variation.  Rapid return is free of cam actuation.

Fluid Types Any type of hydraulic fluids listed in the table below can be used.

 Please maintain the degree of contamination within NAS 1 638-Grade 12.  Use 25 μm or finer line filter.

1/4-20 UNC × 2-1/4 Lg.  1/4-20 UNC × 2-1/4 Lg.  1/4-20 UNC × 2-1/4 Lg.  

and a  check valve and used mainly for controlling rapid traverse and feed cycles machine tools. 

 Switching from rapid traverse to feed is made by a cam operation, 

Note:For use with hydraulic fluids other than those listed above,please consult your Yuken representatives in advance.

Attachment Mounting Bolts 

3/8-16 UNC × 2-3/4 Lg.  3/8-16 UNC × 2-3/4 Lg.

Allowable pressures at controlled flow outlet If internal drain types of UCF1G-01

 Spool push down level Limit the spool push down level within the allowable maximum stroke range shown 

 In addition, connect the drain pipe independently and directly to the tank.

 (This applies only to external drain types.)

Control of Contamination Due caution must be paid to maintaining control over contamination of 

or 03 or UCF2G-03 a re used, use them in metre-out circuits in order to limit the valve outlet 

pressure to the valves shown below.  In addition, external drain types can also be used in metre-in circuits.

Minimum required pressure difference The minimum pressure differential between inlet

 and outlet port is required to obtain the optimum pressure compensation. 

 It varies accordingly to the flow rate to be s et.  For details, refer to the performance curve.

日本YUKEN進(jìn)給控制閥技術(shù)樣本

標(biāo)簽

近期瀏覽:

在線客服
亚洲日韩Av中文字幕无码,国产精品自产拍在线观看中文,久久亚洲春色中文字幕久久久,亚洲性爱无码视频在线观看