E290C52V0XEFCV1,NUMATICS兩通電磁閥
上海乾拓貿(mào)易有限公司
電話:021-69000965
傳真:021-39529830-8007
手機(jī):17321056802 (微信就是手機(jī)號(hào))
郵箱:17321056802@163.com
企業(yè)QQ:2880626084
聯(lián)系人:鄭娜
? High flow due to angled seat design
? Anti-waterhammer design (fluid entry under the disc)
Connector Spade plug (cable ? 6-10 mm)
? The valves satisfy all relevant EC Directives and
with the provisions of the DirectiveRoHS 2
Visualisation valve (switching) LED
Electrical safety (adapter AC to DC) IEC 335 (EN-IEC 60730), class 2
Electrical enclosure protection IP65 (EN 60529)
Standard voltages DC (=) : 24V ±10 %, max. ripple 5%
(EN-IEC 61131-2) AC (~) : 110V to 250V / 50-60 Hz
Actuator rotatable through 360°
Connector specification ISO 4400 / EN 175301-803, form A
Motor consumption 12 W in operation, 0 W hold
Max. peak current: 0,7 A
環(huán)境溫度范圍-10°C至+ 50°C
-10°C至+ 40°C(145°C蒸汽)
較大粘度600 cSt(mm2 / s)
執(zhí)行時(shí)間<1,3 s(開(kāi))/ <1,3 s(關(guān)閉)
空氣和氣體組1&2
水,油,液體組1&2 -10°C至+ 90°C NBR(腈)
蒸汽達(dá)+ 145°C FPM(含氟彈性體)
? Fluid isolation between electrical actuator and valve body
? LED valves status display
? The valves satisfy Pressure Equipment Directive 2014/68/EU, article 3.3
? The motorised valves comply with the essential requirements of EMC Directive
2014/30/EU (EN-IEC 61000-6-2 and EN-IEC 61000-6-4) and
Low Voltage Directive2014/35/EU (EN-IEC 60730)
? Vacuum operation up to 10-2 mbar
? In option closing of the valve in case of power failure
差壓見(jiàn)“規(guī)格”[1 bar = 100 kPa]
較大允許壓力10 bar
E290C52V0XEFCV1,NUMATICS兩通電磁閥
021-39526589
網(wǎng)址:m.sh-hancheng.cn
地 址:上海市嘉定區(qū)嘉涌路99弄
6號(hào)樓713室